CDS-2010U(F)
Cable Fault Locators
Features and Benefits
With its 20 kV output, the CDS-2010U(F) is good for fault locating cables rated up to 35 kV with a line to ground voltage of 20 kV. The high burn current of 400 mA can be used to condition a fault to reduce its arc overvoltage to permit thumping at a lower and less damaging voltage level, still at full energy. The CDS-2010U can thump a cable at just 5 kV while delivering 1000 joules. Find your fault without creating the next one.
Features:
- Constant energy, three output voltage taps at full energy
- Fully variable hipot output on all voltage taps
- TDR-ready, arc-reflection and current pulse methods
- Built in high voltage coupler for TDR interconnect
- Variable discharge rate
- High burn currents
- Portable, hand truck mounted
Specifications
Input: | 120 V, 60 Hz, 20 A (F) 230 V, 50/60 Hz, 10 A |
---|---|
Hipot Output: | 0 – 5/10/20 kV DC |
Hipot Burn Current: | 400/200/100 mA @ 5/10/20 kV output settings |
Discharge Output: | 1000 J at each output voltage when 100% 1 |
Discharge Rate: | 6 – 10 seconds |
TDR Interface: | Internal – arc reflection and current impulse |
Size & Weight: (W x D x H) | 27 x 27 x 48 in., 260 lb. 686 x 686 x 1219 mm, 118 kg |
Output Termination: | 50′ HV EPR, return, and ground EPR output cable remains flexible in cold weather |
Other Features: | Rugged, transit protected meters External interlock Emergency OFF mushroom switch Internal heater to limit condensation |
1. This model can discharge 1000 J at only 5 kV.
CDS-2010U(F)
电缆故障定位器
特色和优点
凭借其20 kV输出,CDS-2010U(F)适用于额定电压高达35 kV且线对地电压为20 kV的故障定位电缆。400 mA的高燃烧电流可用于调节故障以降低其电弧过电压,从而允许在较低且破坏性较小的电压水平下进行重击,仍然处于全能量状态。CDS-2010U可以在5kV的电压下重击电缆,同时提供1000焦耳。
特征:
- 恒定能量,三个输出电压以全能量抽头
- 所有电压抽头均可输出完全可变的高压输出
- TDR就绪,电弧反射和电流脉冲方法
- 内置高压耦合器,用于TDR互连
- 可变放电率
- 高燃烧电流
- 便携式,手推车安装
产品规格
输入: | 120 V,60 Hz,20 A (F)?230 V,50/60 Hz,10 A. |
---|---|
高压输出: | 0 – 5/10/20 kV DC |
Hipot Burn Current: | 400/200/100 mA @ 5/10/20 kV输出设置 |
放电输出: | 当100%1时,每个输出电压为1000 J. |
放电率: | 6 – 10秒 |
TDR接口: | 内弧反射和电流脉冲 |
尺寸和重量:( 宽x深x高) | 27 x 27 x 48英寸,260磅 .686 x 686 x 1219毫米,118千克 |
输出终止: | 50’HV EPR,回程和地面 EPR输出电缆在寒冷天气中保持灵活性 |
其他特性: | 坚固耐用的运输保护仪表 外部联锁 紧急关闭蘑菇开关 内部加热器可限制冷凝 |
这个型号可以在5 kV时放电1000 J.